Nortec 2000D+涡流探伤仪

起批量
1

产品属性

品牌
Olympus/奥林巴斯
型号
Nortec 2000D+
加工定制
其他
重量
详见资料

Nortec 2000D

Nortec 2000D

Nortec 2000D 

Nortec 2000D+涡流探伤仪具有以下功能:50 Hz12 MHz的频率范围、单频或双频操作、使用方便的数字式电导率,还可支持旋转扫查器。因此这款设备成为多种航空航天材料无损检测应用的理想探伤仪。 

The Nortec 2000D+ offers a frequency range of 50 Hz to 12 MHz for applications ranging from detection of cracks in tubes or structures to the discovery of minute flaws in aircraft materials. Single or dual frequency operation, easy to use digital conductivity, and rotating scanner support make the flaw detector ideal for numerous aerospace NDT applications. 

Customer-interchangeable displays offer excellent visibility in any lighting condition. A VGA output drives a heads up display for inspection where conditions may be cramped or a large desktop monitor or projector for classroom training. 

At less than 4 lbs (1.8 Kg), the rugged Foreign Object Debris (FOD) free case will survive harsh field and production environments. An adjustable tilt bail and anti-slip bumper allow the unit to be placed on just about any surface. 

The Nortec 2000D+ incorporates our unique PowerLink™ software, which provides automatic probe recognition and documentation. The instrument can be set-up by recalling the program stored in the PowerLink™ chip, providing integrity and repeatability of inspection results. 

As many as 120 programs can be stored and recalled later. Date and time are recorded with each set-up and are easily identified with alphanumeric values up to 29 characters long. 20 memory locations are available to store eddy current displays.. 

Features 

• 50 Hz - 12 MHz frequency range 
• Single Li-Ion battery 
• Lightweight, less than 4lbs. (1.8 Kg) 
• Digital conductivity in International Annealed Copper Standard (%IACS) or Mega Siemens per meter (MS/m) 
• Non-conductive coating readings in inches or millimeters 
• Multiple scanner support 
• Internal balance loads for single coil probe support 
• Customer interchangeable displays: 
- Hi-Brite Electroluminescent 
- Monochrome Liquid Crystal 
- Color Liquid Crystal 
• Dual Frequency 
• VGA Output 
• Display Freeze to hold flaw signals 
• PowerLinkTM Technology - automatic probe recognition and instrument set-up 
• Split screen presentation with color coded soft keys 
• On screen reference memory for go/no go applications 
• On board storage of 120 programs 
• Waterfall display 

Nortec 2000D+ Specifications* 

BASIC PERFORMANCE

FrequencyRange: 50 Hz - 12 MHz 

Gain: 0 - 90 dB in 0.1 dB steps. The horizontal and vertical gains may be adjusted separately or together. 

Rotation: Variable 0º - 359º 

Sweep: Variable from 0.005 - 4 seconds per division 

LowPassFilter: 10 - 500 Hz and wide band 

HighPassFilter: Off, 2 to 500 Hz. 2 pole response 

Probe Drive: 2, 6, 12 volts 

Variable Persistence: Screen persistence can be varied from 0.1 - 5 seconds. 

Probe Types: Absolute and differential in either bridge or reflection configuration. The instrument is fully compatible with NORTEC PowerLink™ probes. 

Alarms: Can be set to trigger on positive or negative 

Alarm Modes: 1-3 box gates, polar, sweep, conductivity, and coating thickness 

Trace Storage: 20 traces can be stored for recall. The traces can be static or frozen. They can contain up to 60 seconds of movement. The traces are stored with the date and time of capture. 

Program Storage: 120 instrument set-ups may be stored and recalled. The date and time of storage is recorded with each set-up. 

Print Out: Provides a custom configurable report header containing the display screen data and probe parameters including serial number (PowerLink™ probes only) 

Printers: Any serial printer 

 

Inputs / Outputs

Power: 7-pin connector to charge the internal battery and operate the instrument on AC power 

RS-232: DB-9P connector, bi-directional serial data via RS-232 

Probe Connector: 16-pin LEMO 

Analog Outputs: Horizontal and Vertical outputs of both F1 and F2. +/- 5 volts, 1 volt per division 

Alarm Outputs: 9-pin analog and alarm output connector 

VGA Output

 

General

Dimensions: 9.5" L x 5.5" H x 3.6" D (215 mm x 165 mm x 92 mm) 

Weight: 3.8 lbs. (1.7 Kg) with battery 

Display: Customer-interchangeable QVGA displays (320 x 240 pixels): color or monochrome LCD, Hi-Brite electroluminescent 

Operating Temperature: 14° F to 122° F (-10° C to 50° C), depending on configuration 

Storage Temperature: -60° F to 160° F (-51° C to 71° C), depending on configuration 

Humidity: 5 to 95% 

Classification: Based on Class 2 specifications from the MIL-PRF-28800F handbook 

Altitude: Maximum operating and non-operating altitude - 15,000 ft. (4600 m) 


Hazardous Area Operation: Safe operation as defined by Class I, Division 2, Group D, as found in the National Fire Association Code (NFPA 70), Section 500, and tested using MIL-STD-810F, Method 511.4, Procedure 1 

Power 
Power Requirements: 85 to 240 volts, 50-60 Hz. External holder charges batteries outside the instrument. Charging time is typically 4 hours. 
Low Battery Protection: Display bar graph "gas gauge" indicates approximate operating time. 
Battery Operating Time: 8 hours (nominal depending on configuration) 

Conductivity 
Frequency: 60 kHz or 480 kHz 
Probe Type: NORTEC Conductivity Probe 
Digital Conductivity Specification: Digital conductivity display from 0.9% to 110% IACS or 0.5 to 64 MS/m. Accuracy within +/- 0.5% IACS from 0.9% to 65% IACS and within +/- 1.0% of values over 62%. Meets or exceeds BAC 5651 specifications. 
Non-Conductive Coating Thickness: Can measure non-conductive coating thickness from 0" to 0.015" (0 to 0.38 mm). Accuracy of +/- 0.001" (0.025 mm) over 0.00 to 0.015" (0 to 0.38 mm) range 

Scanners 
Scanner Compatibility: Will operate all Olympus Nortec and other commercially available scanners 
Waterfall Display: Stores up to 60 sweeps per hole and includes an on screen readout of the distance to the defect from the start of the scan (PS-5 only) 

Dual frequency 
Frequency Extension: 50 Hz to 12 MHz 
Second Frequency: 50 Hz to 3 MHz, 2nd frequency is an exact division of the first frequency in ratios of: 1/2 (F1 < 6 MHz), 1/4, and even divisors to 1/32. 
Display: Frequency 1 (F1) only, Frequency 2 (F2) only, sum of F1 and F2, difference between F1 and F2, split screen with selected combinations of F1 and F2 and mixed frequencies 
High Pass Filter: Available in Frequency 1 (F1) only 

Standard Inclusions 
Operating Manual 
Power Cord 
Li-Ion Battery 
Universal Barrery Charger 
Carry Case 
Protective Soft Cover 
VGA Cable 
Calibration Certificate 

*All specifications are subject to change without notice. 

The Nortec 2000D+ offers a frequency range of 50 Hz to 12 MHz for applications ranging from detection of cracks in tubes or structures to the discovery of minute flaws in aircraft materials. Single or dual frequency operation, easy to use digital conductivity, and rotating scanner support make the flaw detector ideal for numerous aerospace NDT applications. 

Customer-interchangeable displays offer excellent visibility in any lighting condition. A VGA output drives a heads up display for inspection where conditions may be cramped or a large desktop monitor or projector for classroom training. 

At less than 4 lbs (1.8 Kg), the rugged Foreign Object Debris (FOD) free case will survive harsh field and production environments. An adjustable tilt bail and anti-slip bumper allow the unit to be placed on just about any surface. 

The Nortec 2000D+ incorporates our unique PowerLink™ software, which provides automatic probe recognition and documentation. The instrument can be set-up by recalling the program stored in the PowerLink™ chip, providing integrity and repeatability of inspection results. 

As many as 120 programs can be stored and recalled later. Date and time are recorded with each set-up and are easily identified with alphanumeric values up to 29 characters long. 20 memory locations are available to store eddy current displays.. 

Features 

• 50 Hz - 12 MHz frequency range 
• Single Li-Ion battery 
• Lightweight, less than 4lbs. (1.8 Kg) 
• Digital conductivity in International Annealed Copper Standard (%IACS) or Mega Siemens per meter (MS/m) 
• Non-conductive coating readings in inches or millimeters 
• Multiple scanner support 
• Internal balance loads for single coil probe support 
• Customer interchangeable displays: 
- Hi-Brite Electroluminescent 
- Monochrome Liquid Crystal 
- Color Liquid Crystal 
• Dual Frequency 
• VGA Output 
• Display Freeze to hold flaw signals 
• PowerLinkTM Technology - automatic probe recognition and instrument set-up 
• Split screen presentation with color coded soft keys 
• On screen reference memory for go/no go applications 
• On board storage of 120 programs 
• Waterfall display 
• Windows-based EddyMaster™ Software 

 




规格参数
型号 Nortec 2000D+   品牌 Olympus/奥林巴斯  
加工定制 是   测量范围 详见资料  
尺寸 详见资料   分辨率 详见资料  
类型 涡流探伤仪   重量 详见资料  
包装参数
体积(m²)
产品重量(kg)
代理商供货
退换货规则说明
申请方式

1,在线申请:您可以在"我的订单"中找到您需要退换修的订单,点击”申请退款/退货”即可。我们的工作人员会在2个工作日 内和您取得联系,你可以随时在线查看你的退换修状态。

注意事项

1,“7天无理由退换货”适用于买家在收到货品后因不满意货品希望退换货的情形。

2,因质量问题产生的退换货,邮费由平台供应商承担(此质量问题为货品破损或残缺)。非商品质量问题的退换货,应由买家承担往返运费。

3,退换货要求退换的商品在平台供应商收到时有完整的外包装、配件、标牌等;待退换的物品被用过、人为破坏或标牌拆卸的不予退换。

(1)符合退货政策的商品必须包装完整、数量准确且不影响再次销售,退货的同时必须退回相应的发票和相关文件。

(2)请对寄回的商品妥善包装,若是退换货过程中由于包装过于简单造成的物流损坏,平台供应商不承担商品完整责任。

(3)发票需单独寄送。退换货时,如涉及发票退回,请您不要将发票放在货物中一起寄送,平台供应商客服人员将和您确认发票寄送地址,避免丢失。

4,退货商品的价款到账时间因支付方式的不同而有所差异,具体应参照相关银行或支付工具的说明提示,平台供应商不对退换货费用的到账时间做任何形式的保证。

特别提醒:为避免由于商品滞留造成的经济损失,所有退换货商品,买家应在所规定之时间内发回(以物流签收时间次日起7天内为准),超过规定时间仍不能将退换商品发出的,平台供应商将不予接受该退换货商品。

联系方式
注意:1 . 使用电话联系可有效保证您的号码隐私不被泄露
          2 . 拨打后可在后台进行拨打记录查询
          3 . 成交后在会员中心确认可获得积分
联系人:张爱丽 (市场部/市场经理)
电话:13684941024
给我留言
注意:1. 供应商将在24小时内给您回复,回复内容将以短信形式发送至您手机。
2. 对产品的尺寸,质量,规格,库存等方面技术问题进行咨询,我们有专人进行回复,因厂家随时会更改产品的相关信息,请以厂家实际产品为准。
咨询产品:
Nortec 2000D+涡流探伤仪
联系电话:
联系人:
留言详情: